Pharmaceutical Analysis MCQ: 30 Best Free Questions with Answers

Pharmaceutical analysis MCQ questions cover two parts: classical titrations and instrumental methods such as UV, IR, HPLC and chromatography. This quiz has 30 questions that test both, along with basic terms like accuracy, precision and limit of detection.

It is useful for D.Pharm, B.Pharm and GPAT preparation, and for anyone who wants to work in a quality control lab.

Start the Pharmaceutical Analysis MCQ quiz

There are 30 questions with four options each. Try to finish without looking at your notes, then use the explanations further down to fix your weak spots.

Pharmacy Quiz 10 - Pharmaceutical Analysis

1 / 30

The Beer-Lambert law relates absorbance to

2 / 30

The ultraviolet region of the spectrum lies between

3 / 30

The visible region of the spectrum lies between

4 / 30

The fingerprint region of an IR spectrum lies between

5 / 30

IR spectroscopy is mainly used to identify

6 / 30

NMR spectroscopy uses

7 / 30

Mass spectrometry measures the

8 / 30

In HPLC the mobile phase is delivered by a

9 / 30

A commonly used detector in HPLC is the

10 / 30

The mobile phase in gas chromatography is an

11 / 30

The commonly used stationary phase in TLC is

12 / 30

The Rf value is the

13 / 30

The Rf value always lies between

14 / 30

Paper chromatography is based mainly on

15 / 30

A suitable indicator for titration of a strong acid with a strong base is

16 / 30

Starch is used as an indicator in

17 / 30

EDTA titrations are examples of

18 / 30

Eriochrome Black T is used as an indicator in

19 / 30

Potassium chromate is the indicator used in

20 / 30

Perchloric acid in glacial acetic acid is used to titrate

21 / 30

Potassium permanganate titration is a

22 / 30

Normality is defined as the number of

23 / 30

Molarity is defined as the number of

24 / 30

A standard solution is a solution

25 / 30

Which of these is a primary standard?

26 / 30

Accuracy of an analytical method refers to the

27 / 30

Precision of an analytical method refers to the

28 / 30

The limit of detection (LOD) is the

29 / 30

Polarimetry is used to measure

30 / 30

The electrode commonly used in a pH meter is the

Your score is

The average score is 0%

How Pharmaceutical Analysis is asked in exams

Analysis is a subject where understanding helps more than memory. If you know why starch is used in iodometry or why NaOH is not a primary standard, you can answer many variations of the same question. Students lose marks mainly in indicators, wavelength ranges and chromatography terms, so these are the areas to revise with care.

Pharmaceutical Analysis MCQ mistakes students make, and the logic behind them

These are the questions from the set above that students most often get wrong, with the reason behind each answer.

  1. What does the Beer-Lambert law relate absorbance to?
    Answer: Concentration and path length. Absorbance increases in direct proportion to both.
  2. What is the Rf value and what is its range?
    Answer: Distance travelled by solute divided by distance travelled by solvent front; it lies between 0 and 1. It can never be more than 1 because the solute cannot move farther than the solvent.
  3. Which indicator is used in iodometric titrations?
    Answer: Starch. Eriochrome Black T is for complexometric titrations such as water hardness, and potassium chromate is used in Mohr’s method.
  4. What does perchloric acid in glacial acetic acid titrate?
    Answer: Weak bases, in non-aqueous titration. Weak bases do not give sharp end points in water.
  5. Which of these is a primary standard?
    Answer: Potassium hydrogen phthalate. Sodium hydroxide absorbs moisture and carbon dioxide, so it is not stable enough.

Quick revision points for Pharmaceutical Analysis

  • The ultraviolet region is 200 to 400 nm and the visible region is 400 to 800 nm.
  • The fingerprint region of an IR spectrum lies between 1500 and 400 cm-1, and IR is mainly used to identify functional groups.
  • NMR uses radiofrequency radiation in a magnetic field, and mass spectrometry measures the mass-to-charge ratio of ions.
  • HPLC uses a high-pressure pump, gas chromatography uses an inert carrier gas, and TLC commonly uses silica gel.
  • Accuracy is closeness to the true value, precision is closeness of repeated results, and LOD is the lowest amount that can be detected.
  • A pH meter uses a glass electrode, and polarimetry measures optical rotation.

A simple way to learn from your mistakes

Make a table of titrations with four columns: type of titration, example, indicator and use. Fill it from your notes and check it against the answers you missed in this pharmaceutical analysis MCQ quiz. Also keep one page for wavelength and wavenumber ranges. These two pages cover a large part of the MCQs.

Frequently asked questions about pharmaceutical analysis MCQ

Is pharmaceutical analysis difficult?

It is easy if you understand the principle behind each method. Rote learning without understanding often leads to mistakes in indicators and ranges.

What topics are asked most often?

Titrations, indicators, UV and IR spectroscopy, chromatography and validation terms such as accuracy and precision.

Is this quiz good for GPAT?

It covers the basic level of analytical chemistry that forms the base for GPAT questions.

Keep practising

If this pharmaceutical analysis MCQ set felt comfortable, move on to the next subject. These pages will help:

For official syllabus details and regulations, refer to Indian Pharmacopoeia Commission and Pharmacy Council of India.

Written by the Noteskarts pharmacy education team. This quiz is for exam practice and learning only; always check your latest syllabus and standard textbooks for final answers.

Noteskarts

Hello Welcome to Noteskarts. I hop this article help you. thank you for visit.

Leave a Reply